Power & Climate
Electrotechnology
The working words of power systems, protection, earthing and the grid control room.
- 109 terms
- 28 shop talk
- 8 topics
Electrotechnology is the shared vocabulary of everyone who generates, moves, protects and measures electricity, from the engineer running a fault study to the operator on the night desk of a grid control room. Much of it is defined with real precision, because a word like creepage distance or overvoltage category ends up as a number on a drawing and a dimension on a product. The same people also talk in a fast, clipped jargon on the radio and in the substation yard, and both registers sit side by side here.
The formal core covers power flow and power quality (active power, reactive power, power factor, harmonics, sag and swell), protection (fault current, IDMT curves, distance protection, differential protection, selectivity), earthing (the TN, TT and IT systems, equipotential bonding, touch voltage) and insulation coordination (BIL, clearance, CTI, partial discharge). EMC and measurement terms such as common-mode noise, true RMS and the insulation resistance test complete the toolkit.
Control-room and substation talk is where outsiders get lost. A breaker kicks, a relay flags, the 86 is latched, a feeder blinks, a squirrel takes out a transformer. Crews rack out a breaker, tag out the isolation points, prove dead, hang portable earths and work under a permit to work. They megger a cable, hipot a joint, ductor a contact and bring the thumper out to find a cable fault. Plenty of everyday words carry narrow meanings: stiff, dead, hot, trip, reach, burden and slip.
What marks an insider is precision about safety words and units. Nobody experienced calls a circuit dead until it has been proven dead, nobody mixes up kW, kVA and kvar, and anyone who swaps a disconnector for a circuit breaker in a switching order gets stopped. Regional habits matter too: British speakers say earth, isolator and discrimination where North Americans say ground, disconnect and coordination.
Who talks like this: Power system engineers, protection and control engineers, substation operators, grid dispatchers, high-voltage electricians, line crews, test technicians, EMC engineers and electrical designers.
Start here: ten words every newcomer needs
Power factor
Ratio of active power to apparent power, showing how much of the current drawn does useful work.
Fault current
Abnormally high current that flows when insulation fails and a short circuit or earth fault forms.
Earthing system
Arrangement describing how a supply's neutral and an installation's exposed metalwork are connected to earth.
Protection relay
Device that watches currents and voltages and orders a circuit breaker to trip when it detects a fault.
Creepage distance
Shortest route over an insulating surface from one conductive part to another, the dimension that resists tracking.
Harmonics
Voltage or current components at whole multiples of the supply frequency, produced mostly by nonlinear loads.
RCD
Residual current device: trips when the current going out on the live conductors does not all come back.
Switching order
Written step-by-step sequence of operations used to isolate or restore equipment safely.
Arc flash
Explosive release of heat, light and pressure when an electric arc forms through air between energised parts.
Prove dead
To test isolated equipment with a verified voltage detector and confirm no voltage before anyone touches it.
Overheard on the job
Real-sounding lines from the floor, translated into plain English.
Line 4 tripped on zone 1, reclose failed so it's locked out, and the 86 on the transformer flagged as well.
TranslationThe line's distance protection saw a fault in its first, undelayed zone; the automatic reclose did not hold, so the breaker stays open, and the transformer's lockout relay also operated and is showing its indicator.
Rack it out, tag it out, prove it dead and get the earths on before I write the permit.
TranslationWithdraw the breaker to its isolated position, hang danger tags on the isolation points, test for absence of voltage, and apply portable earthing leads before the permit to work is issued.
That bus is soft, every time the crusher starts we sag to 0.85 pu and the drives kick.
TranslationThe supply has high source impedance, so starting the crusher motor drops the voltage to 85 percent of nominal and the variable-speed drives trip on undervoltage.
Megger's fine but the Doble numbers on that bushing have doubled, I'd pull it before it lets go.
TranslationThe insulation resistance test passed, but the insulation power factor test shows the bushing's losses have risen sharply, so it should be replaced before it fails.
Voltage THD is over 8 percent with all the drives on, and the fifth is going to ring with those caps.
TranslationTotal harmonic distortion of the voltage is above 8 percent with every drive running, and the fifth harmonic is close to the resonant frequency of the capacitor bank.
We're not N-1 with Westside out, so hold that switching order until after the evening peak.
TranslationWith the Westside line out of service, losing one more element would overload the system, so planned switching should wait until demand falls.
Squirrel on the bushing, the feeder blinked twice and then locked out.
TranslationAn animal bridged a transformer bushing to earth; the recloser tried twice, causing two momentary outages, then stayed open because the fault persisted.
Power Systems & Grid
16 termsHow power flows, how its quality is described and how grid operators keep supply and demand in balance.
- Active poweralso real power, true powerThe part of electrical power that does real work, averaged over each cycle and measured in watts.
- Apparent poweralso SProduct of RMS voltage and RMS current, the figure transformers, generators and UPS units are rated on.
- Black startalso blackstartRestarting a power system from total shutdown using generators that can start without any outside supply.
- Brownoutalso sustained undervoltageSustained drop in supply voltage, caused by overload or applied on purpose to cut demand during a shortage. Shop talk
- Busalso busbar, bus barRigid conductor or common node in a substation or switchboard where several circuits connect and share power.
- Harmonicsalso harmonic distortionVoltage or current components at whole multiples of the supply frequency, produced mostly by nonlinear loads.
- Islandingalso loss of mains, LOMCondition where part of a network stays energised by local generation after being cut off from the main grid.
- Load sheddingalso load shed, rolling blackoutsDeliberate disconnection of blocks of customer load to stop frequency or voltage from collapsing.
- N-1 criterionalso N minus one, single contingency criterionPlanning rule that a grid must stay within limits after losing any single major element such as a line or generator.
- Per-unit systemalso per unit, puShorthand that states voltages, currents and impedances relative to chosen base values, so 1.0 means nominal.
- Power factoralso PFRatio of active power to apparent power, showing how much of the current drawn does useful work.
- Reactive poweralso vars, QPower that surges back and forth between the source and the fields of inductors and capacitors, doing no net work.
- Sagalso voltage sag, voltage dipBrief drop in RMS supply voltage, usually to between 10 and 90 percent of nominal, lasting up to about a minute.
- Stiffalso strongDescribes a supply with low source impedance, so its voltage barely moves when load or fault current changes. Shop talk
- Swellalso voltage swellShort-lived rise in RMS voltage above normal, often seen on the healthy phases during an earth fault.
- THDalso total harmonic distortionTotal harmonic distortion: the combined size of all harmonics relative to the fundamental, as a percentage.
Protection & Faults
18 termsFault currents, the relays and breakers that clear them, and the settings that decide which device trips first.
- 86 relayalso 86, lockout relayLockout relay that latches after a serious trip and holds breakers open until someone resets it by hand. Shop talk
- Explosive release of heat, light and pressure when an electric arc forms through air between energised parts.
- Auto-reclosealso autoreclose, reclosingAutomatic closing of a breaker shortly after a fault trip, restoring supply when the fault was only transient.
- Blinkalso momentary, momentary interruptionMomentary outage customers see when an upstream breaker or recloser trips and recloses on a passing fault. Shop talk
- Breaking capacityalso interrupting rating, interrupting capacityHighest fault current a circuit breaker or fuse can interrupt safely at its rated voltage.
- Differential protectionalso 87, diffScheme that compares current entering and leaving a protected zone and trips when the two disagree.
- Distance protectionalso impedance protection, 21Line protection that measures impedance to a fault and trips fastest for faults close to the relay.
- Earth faultalso ground fault, line-to-ground faultFault in which a live conductor makes unintended contact with earth or with earthed metalwork.
- Fault currentalso short-circuit current, fault levelAbnormally high current that flows when insulation fails and a short circuit or earth fault forms.
- IDMTalso inverse time overcurrent, 51Inverse definite minimum time: an overcurrent curve that trips faster as current rises, down to a set minimum.
- Nuisance tripalso false trip, spurious tripProtective device opening with no real fault present, usually from bad settings, leakage or transients. Shop talk
- Pickupalso pick-up, operate valueThreshold at which a protection element starts to operate, and the moment the measured value crosses it.
- Protection relayalso protective relay, relayDevice that watches currents and voltages and orders a circuit breaker to trip when it detects a fault.
- Reachalso zone reachExtent of line or network a distance relay zone is set to cover, expressed as an impedance.
- Selectivityalso discrimination, coordinationArranging protection so only the device nearest a fault operates and the rest of the system stays in service.
- Short circuitalso shortUnintended low-impedance path between conductors at different potentials, bypassing the load.
- Tripalso trip out, trip-outTo open a circuit breaker automatically through its protection, or to order a breaker open by command.
- X/R ratioalso X over RRatio of reactance to resistance in the fault path, which sets how large and slow the DC offset in fault current is.
Earthing & Safety
17 termsEarthing systems, bonding, shock voltages and the words that separate a safe isolation from a dangerous one.
- Deadalso de-energised, de-energizedIsolated from every source, proven free of voltage and safe to work on. Shop talk
- Earth fault loop impedancealso Zs, loop impedanceTotal impedance of the path a fault current takes from the source, through an earth fault and back again.
- Earthing systemalso earthing arrangement, system earthingArrangement describing how a supply's neutral and an installation's exposed metalwork are connected to earth.
- Equipotential bondingalso bonding, protective equipotential bondingConnecting metal parts together so they sit at one potential and no dangerous voltage appears between them.
- Hotalso live, energizedShop word for live or energised, and in North America the everyday name for a phase conductor. Shop talk
- IT systemalso isolated system, unearthed systemEarthing arrangement in which the source is isolated from earth or earthed only through a high impedance.
- Livealso energised, energizedConnected to a source of voltage, or describing a conductor meant to be energised in normal use.
- PEN conductoralso combined neutral and earth, CNE conductorSingle conductor that serves as both the neutral and the protective earth in a TN-C network.
- Permit to workalso PTW, permitFormal written authority to work on equipment that has been isolated, earthed and declared safe.
- Portable earthsalso grounds, protective groundsRemovable earthing leads clamped onto isolated conductors to short them together and to earth during work. Shop talk
- Prove deadalso test before touch, live-dead-liveTo test isolated equipment with a verified voltage detector and confirm no voltage before anyone touches it. Shop talk
- RCDalso RCCB, GFCIResidual current device: trips when the current going out on the live conductors does not all come back.
- Step voltagealso step potentialVoltage between a person's feet across the ground surface near an earth fault or an earthed structure.
- TN-C-S systemalso PME, protective multiple earthingSupply earthing in which a combined neutral and earth conductor splits into separate ones at the installation.
- Earthing arrangement where the source is earthed and installation metalwork connects back to it by a protective conductor.
- Touch voltagealso touch potential, prospective touch voltageVoltage a person bridges between a hand on faulted metalwork and their feet or other hand during a fault.
- TT systemalso TT earthingEarthing arrangement where the supply and the installation each have their own separate earth electrode.
Insulation & Coordination
12 termsClearances, creepage, impulse levels and the ways insulation degrades and fails.
- BILalso basic insulation level, LIWLBasic lightning impulse insulation level: the peak impulse voltage equipment must withstand without breakdown.
- Clearancealso air clearance, electrical clearanceStraight-line air gap between two conductive parts, the dimension that decides whether a surge can flash across.
- Coronaalso corona dischargeFaint glowing discharge around high-voltage conductors where the air is overstressed, causing noise and loss.
- Creepage distancealso creepage, creep distanceShortest route over an insulating surface from one conductive part to another, the dimension that resists tracking.
- CTIalso comparative tracking indexComparative tracking index: voltage an insulating material withstands before tracking under a wet contamination test.
- Flashoveralso flash-overDisruptive discharge over or around insulation that creates a short circuit through the air.
- Insulation coordinationalso insulation co-ordinationSizing insulation and surge arresters together so any flashover lands at a cheap, self-restoring point, not inside plant.
- Overvoltage categoryalso OVC, installation categoryClass from I to IV ranking equipment by its position in an installation and the surges it must survive.
- Partial dischargealso PD, discharge activityTiny discharge in a void, on a surface or at a sharp edge that never spans the whole insulation, an early sign of decay.
- Pollution degreealso PDGrade from 1 to 4 describing how much conductive dirt and moisture can settle on insulation in a location.
- Surge arresteralso lightning arrester, arrestorDevice that clamps transient overvoltages by diverting surge current to earth, then returns to insulating.
- Trackingalso surface tracking, carbon trackingConductive carbon trail that leakage arcs through dirt and moisture gradually burn across an insulating surface.
Machines & Switchgear
12 termsTransformers, motors, switchgear and the instrument transformers that feed protection and metering.
- Buchholz relayalso gas relay, 63Gas and oil-surge relay in the pipe between a transformer tank and its conservator that detects internal faults.
- Burdenalso VA burden, secondary loadLoad connected to the secondary of an instrument transformer, stated in VA or ohms.
- CTalso current transformerCurrent transformer: an instrument transformer that scales large primary currents down to a standard secondary.
- Disconnectoralso isolator, disconnect switchOff-load switch that provides a visible isolating gap but is not built to make or break load current.
- Inrush currentalso inrush, switch-on surgeLarge transient current drawn when a transformer, motor or capacitive load is first switched on.
- OLTCalso on-load tap changer, load tap changerOn-load tap changer: a transformer switch that changes the turns ratio under load to regulate voltage.
- Potheadalso cable terminationField name for the termination where an underground power cable meets an overhead line or equipment. Shop talk
- SF6also sulphur hexafluoride, sulfur hexafluorideSulphur hexafluoride: a dense, highly insulating gas used to quench arcs in high-voltage switchgear.
- Slipalso rotor slipShortfall between the speed of an induction motor's rotating field and the actual speed of its rotor.
- Switchgearalso SWGR, gearAssemblies of breakers, switches, fuses, busbars and enclosures that control and protect power circuits.
- Vector groupalso vector group designation, connection symbolCode stating how a three-phase transformer's windings are connected and the phase shift between them.
- VTalso voltage transformer, PTVoltage transformer: an instrument transformer that steps high voltage down to a standard level for relays and meters.
EMC & Electronics
8 termsInterference, coupling and the circuit fundamentals behind electromagnetic compatibility.
- Common-modealso CM, longitudinalDescribes signals or noise present equally, in the same phase, on both conductors of a pair relative to ground.
- Crosstalkalso XT, cross-talkUnwanted coupling of a signal from one conductor or channel into a neighbouring one.
- EMCalso electromagnetic compatibilityElectromagnetic compatibility: a product neither upsets nearby equipment with its noise nor gets upset by theirs.
- EMIalso electromagnetic interferenceElectromagnetic interference: unwanted electrical noise that disturbs the operation of a circuit or system.
- ESDalso electrostatic discharge, static zapElectrostatic discharge: sudden flow of built-up static charge that can destroy or upset electronics.
- Ground loopalso earth loopUnintended current path formed when connected equipment is earthed at points of different potential.
- Impedancealso ZTotal opposition a circuit offers to alternating current, combining resistance and reactance, in ohms.
- Tendency of alternating current to crowd toward the surface of a conductor as frequency rises.
Measurement & Testing
10 termsUnits, meters and field tests used to prove equipment healthy before and after it goes into service.
- Clamp meteralso clamp-on ammeter, amp clampHandheld meter whose jaws close around a conductor to measure current without breaking the circuit.
- Doble testalso power factor test, tan delta testInsulation power factor test on transformers, bushings and breakers, named after a well-known test set maker. Shop talk
- Ductoralso micro-ohmmeter, DLROShop name for a micro-ohmmeter used to measure very low contact and joint resistances. Shop talk
- Hipotalso hi-pot, high-potential testHigh-potential test: applying a voltage well above working level to prove insulation will not break down. Shop talk
- Insulation resistance testalso IR test, megger testDC test that applies a high voltage between conductors and earth and reads leakage resistance in megohms.
- Meggeralso megohmmeter, IR testerTo test insulation resistance with a high-voltage DC tester; also the jobsite name for the tester itself. Shop talk
- RMSalso root mean square, effective valueRoot mean square: the effective value of an alternating quantity, giving the same heating as that DC value.
- Thumperalso surge generator, cable thumperField nickname for a surge generator that pulses a faulted cable so the fault can be heard and pinpointed. Shop talk
- True RMSalso TRMSDescribes a meter or reading that computes the real RMS of any waveform, not one scaled from a sine-wave average.
- varalso VAr, volt-ampere reactiveUnit of reactive power, the volt-ampere reactive, written lower case and usually scaled to kvar or Mvar.
Control Room & Substation Talk
16 termsRadio calls, switching language and yard slang from grid control rooms and substations.
- Backfeedalso back-feed, reverse feedPower arriving at a circuit from an unexpected direction, such as a generator or second supply feeding back. Shop talk
- Bumpalso bump test, jogTo energise a motor for a split second to check its direction of rotation before running it properly. Shop talk
- Chatteralso contact chatter, relay chatterRapid repeated opening and closing of relay or contactor contacts, usually from marginal voltage or vibration. Shop talk
- DC groundalso battery earth fault, DC earth faultUnwanted earth fault on a substation battery or DC control supply, which normally floats free of earth. Shop talk
- Dead busalso dead bar, dead busbarBusbar with no voltage on it, the condition that lets a breaker close without synchronising checks. Shop talk
- Flagalso targetIndicator on a protection relay showing which element or phase operated; also the verb for it showing. Shop talk
- Gallopingalso conductor galloping, dancingLarge, slow vertical swinging of overhead line conductors driven by wind on ice-coated wires.
- Hot stickalso hotstick, operating poleInsulated fibreglass pole used to operate, test or earth high-voltage equipment from a safe distance. Shop talk
- Kickalso kick out, popShop verb for a breaker, overload or relay tripping, as in the breaker kicked. Shop talk
- Magic smokealso let the smoke outJoking name for the smoke a burnt-out component releases, as if the smoke were what made it work. Shop talk
- Rack outalso rack-out, withdrawTo wind a withdrawable breaker out of its connected position in metal-clad switchgear to isolate it. Shop talk
- Ring outalso buzz out, bell outTo check continuity and identity of every core of a cable end to end before termination or after a fault. Shop talk
- SCADAalso supervisory, telecontrolSupervisory control and data acquisition: the system that lets a control room watch and switch remote plant.
- Squirrelalso animal contact, squirrel outageControl-room shorthand for an animal-caused fault, typically a squirrel or bird bridging live parts. Shop talk
- Switching orderalso switching programme, switching programWritten step-by-step sequence of operations used to isolate or restore equipment safely.
- Tag outalso LOTO, lock out tag outTo hang a danger tag on an isolation point so nobody operates it while people work downstream. Shop talk
Frequently asked questions
What is the difference between creepage distance and clearance?
Clearance is the gap a spark would jump straight through the air between two conductive parts, and it guards against flashover from voltage peaks and surges. Creepage distance is the route leakage current would crawl over the insulating surface between the same parts, and it guards against tracking caused by dirt and moisture over time. Clearance depends mainly on impulse voltage and overvoltage category, creepage on working voltage, pollution degree and the material's CTI. Creepage can never be less than clearance.
What do TN, TT and IT earthing systems mean?
The first letter describes the source: T means its neutral is directly earthed, I means it is isolated or earthed through a high impedance. The second letter describes the installation's metalwork: T means it has its own earth electrode, N means it connects back to the source neutral through a protective conductor. TN gives fault currents high enough to trip breakers, TT relies on RCDs because fault current passes through soil, and IT keeps running after a first earth fault.
What is the difference between kW, kVA and kvar?
Kilowatts measure active power, the part that does useful work and drives the energy bill. Kilovars measure reactive power, the power that surges in and out of magnetic and electric fields each cycle without doing net work. Kilovolt-amperes measure apparent power, the combination of the two, which is what heats cables and transformers. The ratio of kW to kVA is the power factor, so a 1000 kVA transformer at 0.8 power factor delivers only 800 kW.
What is the difference between a disconnector and a circuit breaker?
A circuit breaker is built to make and break load current and to interrupt fault currents of tens of kiloamperes automatically when its protection tells it to. A disconnector, also called an isolator, only provides a safe isolating gap and is opened after the breaker has already interrupted the current. Opening a disconnector on load draws a dangerous arc, so interlocks and switching orders always put the breaker first and the disconnector second.
What is the difference between a megger test and a hipot test?
A megger test, properly an insulation resistance test, applies a DC voltage of typically 500 V to 5 kV and reports a resistance in megohms or gigohms, which is trended over time to reveal moisture and contamination. A hipot applies a higher voltage, well above the working level, for a fixed time and gives a pass or fail: the insulation either withstands it or breaks down. Crews usually megger first, then hipot.
More from Power & Climate
Know a word we missed?
Every crew has its own vocabulary. Send us the term, what it means and how you hear it used.