A parameter used in the calibration and testing of rotary electrical transformers like resolvers and synchros. It quantifies the deviation from perfect orthogonality between the sine and cosine winding axes. High interaxis error leads to inaccurate position feedback in servo systems and motor controllers.
Heard on the job
The resolver failed the factory acceptance test because the interaxis error exceeded the maximum allowable tolerance.
Also heard as
- interaxis error