Rate of rise

nounStandard termVacuum

Test that isolates a pumped chamber and tracks how fast the pressure climbs, to estimate leaks and outgassing.

A test in which the chamber is valved off from its pumps and the pressure rise is logged over time; the gas inflow is Q = V·Δp/Δt. A real leak gives a straight line that keeps climbing, while outgassing or a virtual leak gives a curve that bends over as surfaces saturate or the trapped pocket empties. Vacuum furnace specifications typically cap it at a figure such as 10 microns per hour.

Heard on the job

Rate of rise on furnace 4 is 25 microns an hour and dead linear, that's a real leak, not wet walls.

Insider tip

Plot rate-of-rise data on linear axes, not a log scale; a straight line on linear axes is the signature of a real leak.

Also heard as

  • ROR
  • leak-up rate
  • leak-back test
  • pressure rise test