Unified Glare Rating, a formula combining the luminance and apparent size of each luminaire, its position in the view and the background luminance. Values typically run from about 10 to 30 and are quoted in steps of 3: around 16 for drafting and fine work, 19 for offices and classrooms, 22 to 25 for industrial work. Manufacturers publish UGR tables for standard rooms, and calculation software computes it for real ones.
Tender calls for UGR under 19 at the workstations, and the cheap panel tables out at 22, so it's out.