Oxidative induction time: a measure of how much antioxidant protection remains in a polyolefin geosynthetic.

Short for oxidative induction time. A small sample is heated in a differential scanning calorimeter under oxygen, and the time before it starts to oxidize shows how much stabilizer is left. Standard OIT runs at 200 degrees C and atmospheric pressure, while high-pressure OIT runs cooler under pressurized oxygen and detects more stabilizer types. HDPE geomembrane specs commonly ask for at least 100 minutes standard or 400 minutes high-pressure OIT.

Heard on the job

OIT came back at 140 minutes on the conformance sample, comfortably over the 100 in the spec.